ANSI/TIA/EIA 568-B
Commercial Building Telecommunications Cabling Standard
Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com. Standards Preservation This section is not part of the original standards documentation. The purpose of this document is to provide an easy to understand, condensed version ofthe original document. A basic level of telecommunications is assumed. For further information on terms and definitions see our Glossary of Terms section. Whether you are renovating your existing cable plant or installing a new one, Cablingdb.com urges you to investigate a standards based solution. This document is not meant to replace the original standards developed by the various standardsbodies and we urge you to purchase the original documents through www.tiaonline.com.

Head Office Suite 202, The Colonnade Building, 27 Nguyen Trung Truc St., District 1, Hochiminh City, Vietnam Tel: 84.8 823-1693 Fax: 84.8 823-1665 Hanoi Office A11, 3/Fl., Horizon Hotel, 40 Cat Linh St., Dong Da District, Hanoi, Vietnam Tel: 84.4 736-7055 Fax: 84.4 733-2470 Website: www.qd-tek.com.vn Email:info@qd-tek.com

A U T H O R I Z E D

&

E X C L U S I V E

D I S T R I B U T O R

ANSI/TIA/EIA 568-B

Commercial Building Telecommunications Cabling Standard

Table of Contents
ANSI/TIA/EIA-568-B.1 COMMERCIAL BUILDING TELECOMMUNICATIONS CABLING STANDARD General Requirements ANSI/TIA/EIA-568-B.2 100 OHM TWISTED PAIR CABLING STANDARDS Backbone Connecting Hardware Cords and Jumpers Horizontal StrandedANSI/TIA/EIA-568-B.3 OPTICAL FIBER STANDARDS Optical Fiber Cabling Components

Addendums

ANSI/TIA/EIA-568-B.1-1 Patch Cord Bend Radius ANSI/TIA/EIA-568-B.1-2 Grounding & Bonding ANSI/TIA/EIA-568-B.1-3 Supportable Distances for Optical Fiber ANSI/TIA/EIA-568-B.1-4 Recognition of Category 6 & 850 Laser Optimized 50/125µm Multimode Optical Fiber Cabling ANSI/TIA/EIA-568-B.2-1 Category 6ANSI/TIA/EIA-568-B.2-2 Revisions to TIA/EIA-568-B.2 ANSI/TIA/EIA-568-B.2-3 Additional Considerations for Insertion Loss and Return Loss Pass/Fail Determination ANSI/TIA/EIA-568-B.2-4 Solderless Connection Reliability Requirements for Copper Connecting Hardware ANSI/TIA/EIA-568-B.2-5 Corrections to TIA/EIA-568-B.2-5 ANSI/TIA/EIA-568-B.3-1 Additional Specifications for 50/125µm Fiber Optic Cables

TransmissionParameter Charts
Category 3 Category Category Category Category Category Category Category Category Category 5e 5e 5e 6 6 6 6 6 6

Cabling, Connecting Hardware, Permanent Link and Channel Cabling and Connecting Hardware Cords Permanent Link and Channel Cable Connecting Hardware Delay Skew Patch Cord Permanent Link Channel

Quang Dung Technology Distribution Company

Page 2 of 62

ANSI/TIA/EIA 568-BCommercial Building Telecommunications Cabling Standard

ANSI/TIA/EIA-568-B.1 Commercial Building Telecommunications Cabling Standard General Requirements
HORIZONTAL CABLING
The definition of horizontal cabling is that portion of the cabling system that extends from the work area outlet, through the cabling in the wall/ceiling/floor and then to the patch panel in the telecommunications room. Thesystem also includes the patch cords at the work area outlet, and patch cords in the telecommunications room. When provisioning for the horizontal cabling system the designer should also consider voice, fire/safety, video, HVAC and EMS. A good design should be aimed at minimizing relocations and maintenance of the horizontal system as it is much more costly to do it later. Topology Horizontalcabling will be installed in a star topology, with each work area outlet being connected via the horizontal cable to the horizontal cross connect in the telecommunications room. Each floor should have its own telecommunications closet, sized as per ANSI/TIA/EIA 569. Any devices required such as baluns and impedance matching devices should not be installed in the horizontal system, but rather, kept...